Vent Silencer – Silencing 101

A brief overview of the design & operation of vent silencers

Stoddard Vent Silencer in operation

A vent silencer is designed to reduce the noise generated in the discharge stream of a venting gas. Stoddard Silencers manufactures silencers for air, steam and other gases and vapors. A diffuser is located at the inlet of the vent silencer to reduce the turbulence created by the decrease from high-pressure to ambient pressure of the gas. The small holes of the diffuser also break down and convert any low-frequency noise present into high-frequencies. This is beneficial as high-frequency noise is easier to be reduced by absorptive acoustical materials located in the vent silencer.

Vent Silencer Applications

Stoddard Silencers offers a different vent silencers for many different types of venting or depressurization systems. The below is a short list of applications where vent silencers are used.

  • Start-Up Vent Silencer for Boiler System Start-Up Valves
  • Steam Vent Silencer for Boiler System Safety Relief Valves (SRVs)
  • Blowdown Silencer: Natural Gas Compressor Station Blow-Down or Blow-off Valves
  • Air Vent Silencer for Blower Process-Line Trim Valves

Vent Silencer Types

  • Stoddard Silencers manufactures 2 Series of Industrial Vent Silencers: the B21 and B15 Series
    • The B21 series offers a single-stage diffuser with a standard degree of silencing
    • The B15 series offers a multi-stage diffuser with a premium degree of silencing
  • The diffuser design employed by Stoddard Silencers on the B21 and B15 vent silencers is non-restrictive and allows the media to depressurize when it enters the primary diffuser.
    • Because the venting media is flowing at atmospheric pressure through the silencer, the silencer itself is not pressurized and is not considered a pressure vessel. Therefore, the Stoddard Silencers B15 and B21 Series silencers do not require ASME Code design or registration.
    • Some system specifications might require ASME Code design, and on request, Stoddard Silencers can provide an ASME Code U-Stamped or CRN Pressure Vessel vent silencer, however, unless specified by the design criteria, this is not typical.

Vent Silencer Sizing

For proper air or steam vent silencer sizing, we require the operating conditions of the system. The information required would be:

  • Vent Media
  • Flow Rate
  • System Pressure (upstream of the valve)
  • System Temperature (upstream of the valve)
  • Required Silenced Noise Level at outlet of silencer
  • Line Size connecting to Silencer (if known)
  • Required Pressure Drop created by silencer (if necessary)
  • Silenced Noise Level required at a specified distance

Utilizing the above information, Stoddard Silencers can design the appropriate vent silencer for your application and provide a quote with our vent silencer design calculations. The silencer sizing will be determined by these conditions, and the inlet connection size can be adjusted to match your line size. Contact Us today to see how we can optimize the silencers on your venting system. Note that when comparing vent silencer proposals, be sure to compare both the overall silenced noise level and the unsilenced noise level. The silencer performance is determined by the difference between the unsilenced and silenced noise level but performance can be overlooked if the starting basis of unsilenced noise level is higher than a competitor’s.

Installation & Design Considerations

  • Combined Inlets: If the system design requires multiple silencers, Stoddard Silencers can combine design a single silencer utilizing multiple inlet flange connections for different process lines to funnel to the same silencer.  Based on line size, flow rates and whether the flows will occur simultaneously can determine the effectiveness of this approach.
  • Nozzle Loads: The inlet and outlet nozzles are not designed to support the weight of the silencer or external piping. The silencer should be isolated from any upstream/downstream piping via an expansion joint or loop to prevent stresses caused by static or dynamic loads as a result of the weight or thermal expansion of piping upstream from the silencer.
  • Silencer Support: Stoddard Silencers recommends utilizing either the A11 Vertical Mounting Legs, A12 Horizontal Mounting Saddles or A14 Horizontal or Vertical Mounting Clips to support the silencer.
  • Water Drain: Both the B21 and B15 series silencers come with a drain near the bottom of the silencer. To prevent collection of water, Stoddard Silencers recommends keeping the drain is open and functional at all times. Heat tracing or insulation may be required based on the location of installation.

Need help determining the correct vent silencer? Use the below fill-in sheet to complete the necessary information for quoting.