Blower Package Noise Control
To reduce the overall noise level of a blower package there are several options available but a basic understanding of the noise being generated should come first. Overall blower package noise is composed of three noise sources: air, mechanical, and vibration. At a distance of three feet from the package these noises all blend together and are indistinguishable. Studies, which Stoddard Silencers has performed on hundreds of blower packages, have demonstrated that silencers take out the majority of the air noise from the blower package to at the point where what noise remains is masked by the other two sources. Therefore, what the customer hears is mechanical and/or vibration noise. We must search out and treat these sources before we consider treating the silencers or using alternate designs.
Each blower package is different but here are the most common treatments:
- If flex connectors are use, lagging them.
- Lining the belt guard with a sound absorbing foam.
- Using a quiet line motor (80 dBA or less at full load).
- Treating the gear end of the blower to deaden it.
- Mechanically isolating all equipment from the base.
- Putting a shroud, lined with sound absorbing foam, around any rotating components not already treated.
- Modify the silencer design.
- Put an enclosure over the blower and motor.
- Put an enclosure over everything.
These treatments are rated by the level of the noise normally emanating from each of the sources given. Depending on the difference between the blower package noise level and the level required, the number of steps required to meet “spec” will vary. These steps are progressive. Doing #7 without doing #1 through #6 not be productive.
Lastly, depending on the package design the positions of treatments #1 through #6 may interchange; however, #7, #8, and #9 almost always work in that order. Stoddard Silencers sales and engineering personnel are available to discuss all of the above, provide computer generated noise calculations using premium silencers for your particular blower package and help with silencer size and model selection.
Leak Tight Silencers – S-167 Air Leak Tight Test
Standard grade industrial silencers are commercially fabricated vessels. The steel used in the construction is commercial grade. The welding is per AWS D1.1, Sections 8.15 and 9.25 “Quality of Welds” static and dynamically loaded structures. These sections allow a certain amount of porosity. The seams of the silencer are lap or butt joint welds. The F & D head to shell are lap joint welds. The nozzles to shell joints are fillet welds. The nozzle to flange is a double fillet weld, the inside and outside edge of each flange is welded together.
When the silencer is welded together, minor pinhole leaks may appear. These pinhole leaks are considered negligible and they are allowed per AWS D1.1.
To quantify as leak tight a test must be conducted on all of the external welds. Bubble tests are visual indication of leaks (Stoddard Specification S-167.) All tests must be performed before painting since painting can produce false positive readings.
Intake Silencers draw air into a system and typically, unless the intake system is pressurized, is not a leakage concern. Discharge Silencers in a pressure system are a leakage concern and given the application will require testing. All testing is performed at an additional charge.
ASME Code vessels are pressure tested as part of their certification and do not require leak testing. The typical industrial silencer is not an ASME Code vessel since it is not to be operated above 15 psi.
Any further questions regarding leak tight construction should be directed to Stoddard Silencers’ at the number shown above or by email at info@stoddardsilencersinc.com
S-167 Air Leak Tight Test
All silencers that require air leak tests will be tested as follows:
- The silencer will have all openings closed & leak tight.
- Air pressure in the silencer will be stabilized at 10 psig and the silencer will hold this pressure for 2 hours.
- A thin film Bubble Test Solution #372E manufactured by American Gas & Chemicals Co., 220 Pegasus Ave., Northvale NJ, 07647 will be applied to all weld areas including the nameplate area. The presence of air bubbles in the thin film solution indicates an air leak.
- Any leak detection will immediately be repaired and that area re-tested for leaks.
Silencer Shell Lagging
There is only one valid reason for lagging the shell of a silencer. That is to control shell noise and thereby reduce the overall noise level of a rotary PD blower package.
All silencers have some shell noise. It is a result of the energy being dissipated within the silencer. Some of this energy is transmitted through the shell to the outside environment. The amount of transmitted energy can be controlled by the use of laminated shells; a measure Stoddard Silencers’ designs incorporate. Even with this measure, some shell noise remains.
There is a widely circulated misconception that controlling this residual shell noise with lagging will reduce the blower package noise level. At best, this is a half-truth.
Blower package noise consists of vibration, mechanical and air noise. At three feet from the blower (the normal measuring point for noise levels) the sources of these noises are indistinguishable. As an example, shell noise cannot be differentiated from belt noise.
Numerous sophisticated noise studies run by Stoddard Silencers have shown that of the eight to ten noise sources present on the standard blower package, shell noise is sixth or seventh in intensity. In addition, the shell noise is 10-12db (decibels) below the most intense noise sources. What this means is the shell noise is masked by the other sources and that it does not add to the overall noise level of the package.
From a practical standpoint then, lagging the silencer without first treating the other more intense noise sources is a waste of effort and money. Lagging must be part of a fully integrated noise control program in order for it to be effective. Any suggestion that simple lagging will cure a packager’s noise problem is therefore, irresponsible.
Stoddard Silencers will provide engineering assistance to help the customer establish a program which will identify and then control the noise sources in a blower package.
In recent years another motive has been falsely given to justify shell lagging.
Food and wastewater treatment applications raise the concern about “blowing out” the acoustic material (“pack”) in a chamber-absorption silencer. Such concern is without justification, IF, the silencer manufacturer uses sound design parameters in the manufacturing of its product. In these cases no “blow-out” will occur. With prudent selection of “pack” material and its retainer, the pack will be secure and will perform its function.
That function is to remove high frequency noise from the air stream before it enters the main body of the silencer thus preventing shell ring. Shell ring is a type of shell noise far in excess of normally accepted levels. If the pack is omitted the shell ring can be masked by lagging; however, this treats the symptom rather than the cause. The high frequency noise is not removed by this approach and continues to remain in the system. On the discharge side of the blower this causes noise and structural problems downstream of the package. On the inlet side, the noise travels back through the silencer and filter (if any) and out into the surrounding environment. Noise does not follow the airflow.
When the blower package is located indoors with the intake filter located outside, the blower package will seem to be within acceptable noise levels. Unfortunately experience has shown that the neighbors will be hearing the high frequency noise that the silencers have not treated. If the air filter is indoors then the personnel working nearby will be exposed to noise levels in excess of OSHA standards.
Through extensive research and development, Stoddard Silencers has engineered silencers with pack sections that provide proper attenuation with the required unit integrity. In thousands of blower applications, Stoddard has not had a case of “blow-out” given proper silencer selection and installation. We would be pleased to assist your company in selection the proper silencer and provide installation advice for any rotary blower package.
We trust this will explain the complex issue of shell lagging and assist the engineer in specifying and the packager in supplying the best engineered and built blower package available.
Transition Speed
Rotary Positive Displacement Blowers (P-D Blowers) generate different noise characteristics depending upon the speed at which they are turning. As a blower’s speed increases the blower begins to generate high frequency noise in addition to the low frequency noise normally associated with P-D Blowers. The speed at which this occurs is called Transition Speed.
The rpm at which this transition occurs is not the same for different sized blowers. To be able to compare one size blower to another the industry uses Pitch Line Velocity. This is the speed of the pitch line (where the gears intersect) of the timing gear in a blower. After numerous experiments with different sized blowers the industry has settled upon the following pitch line velocities as the transition speeds.
- For the blower intake transition speed is 3300 fpm pitch line velocity.
- For the blower discharge transition speed is 2700 fpm pitch line velocity.
- To calculate the pitch line velocity the formula is: GD * .262 * rpm.
- GD = the gear diameter of the blower
- RPM = the rpm of the blower.
To help the user Stoddard Silencers’ catalogues – shown on this web site – have charts which show the rpm at which transition occurs for different gear size blowers. They also show the silencers recommended for blowers operating both above and below transition speed.
It should be noted that these speeds (and corresponding rpm’s) are not immutable. Due to manufacturing tolerances in the blower and sheaves and the tolerance in the speed of the blower motor, transition can occur plus or minus five percent (5%) of the calculated value. Stoddard Silencers recommends that if the customer’s blower is operating close to transition speed choose the silencer best suited for above transition speed blowers.
As an additional note, the overall noise level of a blower package is directly proportional to the pitch line velocity of the blower.
Acoustic Pack Migration
Due to the application involved some customers may have concerns over the migration of the acoustical packing used in industrial silencers. “Migration” is defined as the movement of the acoustical packing material from its location within the silencer into the air stream.
Acoustical packing is mandatory where silencers are used on blowers operating above transition speed. At speeds above transition, blowers generate higher frequency noise that is unable to be attenuated by the standard chamber/reactive silencer. The addition of the acoustical packing removes this objectionable noise before it can impact the silencer shell and cause shell ring. For a more detailed description of transition speed and shell noise please contact Stoddard Silencers, Inc. at (847) 223-8636 (phone), (847) 223-8638 (fax) or via e-mail at info@stoddardsilencersinc.com.
Packing migration is dangerous in applications such as food, plastics and fine bubble diffuser systems used in waste water treatment, to name a few. Stoddard Silencers has over forty-five years experience in the rotary blower market. It is this experience that has allowed them to design an acoustical packing component to the chamber-absorptive silencer that prohibits pack migration.
The design Stoddard Silencers uses is a combination of a finely perforated pack retention tube and a long strand, highly flexible acoustical packing material. Our standard packing material is polyester wool that has a temperature limit of 325o F. For applications where the temperature exceeds this limit, please contact Stoddard Silencers.
When properly selected, installed and maintained, Stoddard Silencers’ designs will not allow packing to migrate. In field studies where Stoddard’s standard design silencers have been removed from service and examined, no pack migration has ever been evident. This is a testament to Stoddard Silencers expert engineering, design and fabrication.
Should there be any other questions regarding acoustical pack migration, please contact Stoddard Silencers at the numbers shown above.
Standard versus Premium Silencers
When specifications call for a “Premium Grade Silencer” there can be confusion as to the definition of a premium grade silencer. Premium grade does not necessarily refer to a chamber-absorption silencer; a silencer that has chambers and tubes but also the inclusion of acoustical pack material to attenuate high frequency noise.
Each style of silencer – both chamber and chamber absorption – has a standard grade and a premium grade. The defining characteristics are different for each.
For chambered silencers – often called reactive – the difference is in the volume of the silencer. For Stoddard Silencers’ discharge silencers the D12 series is the standard grade silencer while the D13 series is the premium grade. Chambered silencers are for blowers operating below transition speed (see separate specification sheet for a definition of transition speed). The D13 has more volume and different internals that cause its attenuation to be greater than the D12. Thus the D13 is a premium grade while the D12 is our standard. For the intake silencers we only use the L41 series which is a premium grade silencer.
For chamber-absorption silencers the difference is the volume of the silencer plus the thickness and length of the acoustical packing section. Chamber absorption silencers are used on blowers operating above transition speed. Stoddard Silencers’ standard grade intake silencer is the L63 series while the L61 is the premium grade intake silencer. Stoddard Silencers’ standard grade discharge silencer is the D32 series while the D33 series is the premium grade.
One last note worth mentioning; in the 6” pipe size silencers and smaller there is minimal difference between the standard and premium grade silencer. For that reason, unless specifically asked for by the customer, Stoddard Silencers only makes the standard grades in 8” pipe size and larger.
If you have further questions about the construction of Stoddard Silencers’ silencers and/or filters please call the factory at (847) 223-8636, send us a fax at (847) 223-8638 or send us an email at Info@StoddardSilencersInc.com.
Installation Operation and Maintenance Instructions