Vent Silencers for Steam & Gas

B21 / B15 Series Vent Silencers

Vent Silencers

The Stoddard Silencers manufatured vent silencer reduces the noise created by high pressure steam or gas. The noise is created by turbulence from the reduction in pressure from being released through a control, relief or safety valve to the atmosphere. Because of the intensity of this noise, it can be a safety concern for those nearby and can be a nuisance to those located further from the source.

By installing a vent silencer downstream of the valve, this noise can be significantly reduced. Custom manufactured vent silencers for the depressurization of your high pressure steam or gas process. Each vent silencer sizing is calculated based on project specific operating conditions. The vent silencer design utilizes the combination of a single or multi-stage diffuser and varying degrees of absorptive treatments. Stoddard Silencers offers several designs to help fine tune the necessary attenuation required by each vent application.

Calculations are available for any vent silencer application with noise levels estimated for any distance.

B15 Series Vent Silencers

B15 Vent Silencers

Application

The Stoddard B15 absorption style vent silencer is recommended for pressurized steam or gas systems venting to atmosphere. These silencers can also be used as discharge silencers on compressor systems.

Design

The B15 silencers utilize a dual-stage diffuser and contain an acoustic absorption section to decrease high frequency noise while expanding to a larger diameter outlet to reduce exit velocity.  Standard design includes a 150# ANSI RFSO inlet and weatherhood covered outlet.

Recommended silencer size is based upon operating conditions. The inlet connection size can be adjusted as necessary to match line size.

Construction

All welded construction of sheet and plate Carbon Steel with 304/316 Stainless Steel available on request. Fiberglass or Mineral Wool acoustic absorption material as appropriate for operation conditions. Exterior surfaces are provided with a shop coat primer or high-heat black finish per application. ASME code, flanged outlet connection, side connections, mounting brackets, or special paint available at extra cost.

B15 – Vent Silencer

ModelPart #ABCWt. (Lbs.)Drawing
B15-492T042104661Login to View
B15-592T052125490Login to View
B15-692T0631660145Login to View
B15-892T0841867-1/2190Login to View
B15-1092T1052080260Login to View
B15-1292T1262495-3/4440Login to View
B15-1492T14626105525Login to View
B15-1692T16830112-1/4820Login to View
B15-1892T18830116-1/21000Login to View
B15-2092T201036129-5/81350Login to View
B15-2292T2210361441500Login to View
B15-2492T2412421541900Login to View
B15-2692T2612421682100Login to View
B15-2892T2814481793400Login to View
B15-3092T3014481913600Login to View
B15-3392T3316541984100Login to View
B15-3692T3618602184900Login to View
B15-4292T4222662627000Login to View
B15-4892T4824722888500Login to View

B21 Series Vent Silencers

Vent Silencers for lower pressure systems

B21 Vent Silencer

Application

The Stoddard B21 absorption style vent silencer is recommended for lower pressure (< 150 PSIG) steam or gas systems venting to atmosphere. These silencers can also used as discharge silencers on compressor systems.

Design

The B21 silencers utilize a single-stage diffuser and contain an acoustic absorption section to decrease high frequency noise while expanding to a larger diameter outlet to reduce exit velocity. Standard design includes a flanged inlet and outlet connection.

Recommended silencer size is based upon operating conditions. The inlet connection size can be adjusted as necessary to match line size.

Construction

All welded construction of sheet and plate Carbon Steel with 304/316 Stainless Steel available on request. Fiberglass or Mineral Wool acoustic absorption material as appropriate for operation conditions. Exterior surfaces are prime coated. Flange connections match 125/150# ANSI bolt pattern. ASME code, weather hoods (rain shields), side connections, mounting brackets, or special paint available at extra cost.

B21 – Vent Silencer

ModelPart #ABCDWt. (Lbs.)2D PDF3D STEP
B21-59450021266596Login to ViewLogin to View
B21-694501312786125Login to ViewLogin to View
B21-894502414868150Login to ViewLogin to View
B21-109450361610610230Login to ViewLogin to View

Download Data Sheets

Download B21 Data Sheet Download B15 Data Sheet Vent Silencer Fill-In Sheet