Inlet Air Filter Silencers (Cartridge Filters)

F64 / F72 Series

Stoddard F64 Air Intake Filter Silencer

The air intake filters & silencers offered by Stoddard Silencers include the F64 and F72 series. The standard models from size 1″ to 8″ are considered air filter silencers while for sizes 10″ – 14″, the units are intake air filters only. Primarily used as air intake filters for blowers, these units can be used wherever ambient air is drawn into a process system to maintain efficiency and prevent performance degradation.

The F64 series includes a paper filter element while the F72 series features a polyurethane filter element. Other air intake filter elements are available on request as shown below. Custom blower filter elements with different dimensions or filtration levels are available on request as well.

F64 Series – Air Intake Filter Silencer

Stoddard F64 Air Intake Filter Silencer

Application

The F64 Air Intake Filters provide maximum air filtration (99% on 1 micron), while the 8″ & smaller units provide additional noise silencing as well. For optimum silencing, the F64 can be paired with a chamber-only or chamber-absorptive intake silencer. When used without an intake silencer, the F64 can mount directly on the inlet of an engine, blower or compressor.

Design

Air is drawn into the F64 housing from the underside with the weatherhood protecting from the elements. Particulate is removed from the airstream as the air passes through the replaceable filter element and moves through the outlet of the housing. The filter element should be replaced when the pressure drop across the element is greater than 15″ W.C. differential. For ease of reference, Stoddard Silencers recommends the use of the A40-108 Pressure Drop Indicator for tracking the performance of the filter element.

Construction

All welded construction of Carbon Steel sheet metal with 304/316 Stainless Steel available on request. For added convenience, the 10-14″ filters utilize an aluminum cover. Filters of size 8″ and smaller are powder coated, while larger are finished with a gray enamel. Outlet connection features either a plate flange matching the 125/150# ANSI bolt pattern or MPT pipe connection. Washable filter elements, pressure drop indicators and custom outlet connections available on request.

F64 – Air Intake Filter and Filter Silencer

ModelPart #A Connection SizeBCDRated CFMWt. (Lbs.)Replacement Element Number2D PDF3D STEP
F64-146041*1″ NPT1047357F8-108Login to ViewLogin to View
F64-1.546042*1.5″ NPT1047807F8-108Login to ViewLogin to View
F64-246043*2″ NPT10471357F8-108Login to ViewLogin to View
F64-2.546044*2.5″ NPT10471809F8-108Login to ViewLogin to View
F64-346045*3″ NPT16582859F8-109Login to ViewLogin to View
F64-446046*4″ NPT165852017F8-109Login to ViewLogin to View
F64-546047*5″ NPT165875019F8-109Login to ViewLogin to View
F64-546140*5″ FLG165875019F8-109Login to ViewLogin to View
F64-646048*
6″ FLG2058123526F8-110Login to ViewLogin to View
F64-846049*8″ FLG201013212550F8-111Login to ViewLogin to View
F64-1046B223*10″ FLG2615 1/220333558F8-137Login to View
F64-1246B26712″ FLG2615 1/220467568F8-137Login to View
F64-1446B26814″ FLG2615 1/220565580F8-137Login to View

Part numbers with (*) are typically in-stock to ship 1-2 days ARO.

F72 Series – Air Intake Filter Silencer

Stoddard F72 Air Intake Filter Silencer

Application

The F72 Air Intake Filters provide standard air filtration (98% on 10 micron), while the 8″ & smaller units provide additional noise silencing as well. For optimum silencing, the F64 can be paired with a chamber-only or chamber-absorptive intake silencer. When used without an intake silencer, the F72 can mount directly on the inlet of an engine, blower or compressor.

Design

Air is drawn into the F72 housing from the underside with the weatherhood protecting from the elements. Particulate is removed from the airstream as the air passes through the washable filter element and moves through the outlet of the housing. The filter element should be replaced when the pressure drop across the element is greater than 15″ W.C. differential. For ease of reference, Stoddard Silencers recommends the use of the A40-108 Pressure Drop Indicator for tracking the performance of the filter element.

Construction

All welded construction of Carbon Steel sheet metal with 304/316 Stainless Steel available on request. For added convenience, the 10-14″ filters utilize an aluminum cover. Filters of size 8″ and smaller are powder coated, while larger are finished with a gray enamel. The outlet connections are either NPT pipe or plate flanges drilled to match 125/150# ANSI bolt pattern. Pressure drop indicators and custom outlet connections available on request.

F72 – Air Intake Filter and Filter Silencer

ModelPart #A Connection SizeBCDRated CFMWt. (Lbs.)Replacement Element Number2D PDF3D STEP
F72-146301*1″ NPT1047359F8-119Login to ViewLogin to View
F72-1.546302*1.5″ NPT1047809F8-119Login to ViewLogin to View
F72-246303*2″ NPT104713510F8-119Login to ViewLogin to View
F72-2.546304*2.5″ NPT104718010F8-119Login to ViewLogin to View
F72-346305*3″ NPT165828520F8-120Login to ViewLogin to View
F72-446306*4″ NPT165852020F8-120Login to ViewLogin to View
F72-546307*5″ NPT165875023F8-120Login to ViewLogin to View
F72-546H338*5″ FLG165875023F8-120Login to ViewLogin to View
F72-646308*6″ FLG2058123540F8-121Login to ViewLogin to View
F72-846309*8″ FLG201013212550F8-122Login to ViewLogin to View
F72-104631010″ FLG2615 1/220333595F8-123Login to View
F72-124631112″ FLG2615 1/2204675100F8-123Login to View
F72-144632414″ FLG2615 1/2205655115F8-123Login to View

Part numbers with (*) are typically in-stock to ship 1-2 days ARO.

Replacement Cartridge Filters

Stoddard Silencers offers multiple options for blower filter elements as listed below. The F64 series comes standard with the paper filter element while the F72 series features a polyurethane element.

Stoddard F8-108 Paper Filter Element

Paper Element (Standard)

  • Moisture-resistant pleated paper media in plastisol end caps with expanded metal on ID and OD for strength.
  • Efficiency: 99% on 1 micron particles and larger.
  • Service: Clean by directing compressed air through filter in apposite direction of air flow (DO NOT WASH), EVENTUALLY ELEMENT WILL NEED TO BE REPLACED.
  • F64/F65 Housing Size
  • 1″ – 2.5″
  • 3″ – 5″
  • 6″
  • 8″
  • 10″ – 14″
  • Part Number
  • F8-108
  • F8-109
  • F8-110
  • F8-111
  • F8-137
Stoddard F8-151 Felt Filter Element

Felt Media Element

  • Washable pleated felt media in plastisol end caps between layers of screen mesh.
  • Efficiency: 98% on 3 micron particles and larger.
  • Service: Rap out excessive dirt and wash in warm water with mild detergent. Rinse thoroughly and rap out excessive water before reinstalling.
  • F64/F65 Housing Size
  • 1″ – 2.5″
  • 3″ – 5″
  • 6″
  • 8″
  • 10″ – 14″
  • Part Number
  • F8-151
  • F8-135
  • F8-134
  • F8-139
  • F8-148
Stoddard F8-132 Wire Mesh Filter Element

Wire Mesh Element

  • Layered epoxy coated screen wire in between plastisol end caps.
  • Efficiency: 90% on 10 micron particles and larger.
  • Service: Soak in hot water and detergent. After rinsing allow filter to dry. Adhesive (light oil) can then be applied at 1.5 to 2 oz./element. Allow excess adhesive to drain off prior to installing.
  • F64/F65 Housing Size
  • 1″ – 2.5″
  • 3″ – 5″
  • 6″
  • 8″
  • 10″ – 14″
  • Part Number
  • F8-129
  • F8-130
  • F8-131
  • F8-132
  • F8-142
Stoddard F8-120 Polyurethane Filter Element

Polyurethane Element

  • Washable polyurethane media with a steel core.
  • Efficiency: 98% on 10 micron particles and larger.
  • Service: Remove foam element from steel center core. Wash element in warm, soapy water. Rinse thoroughly in fresh water and wring out. Install on steel center core and set aside to dry. EVENTUALLY ELEMENT WILL NEED TO BE REPLACED.
  • F72/F65 Housing Size
  • 1″ – 2.5″
  • 3″ – 5″
  • 6″
  • 8″
  • 10″ – 14″
  • Part Number
  • F8-119
  • F8-120
  • F8-121
  • F8-122
  • F8-123

Service Instructions

  1. Turn off air moving device prior to servicing.
  2. Remove wing nut on housing cover. Remove cover.
  3. Check elements and service as shown above for the appropriate element.
  4. Check inside of housing for loose articles before replacing cover.
  5. Replace weatherhood.
  6. Restart the air moving device.

Download Data Sheets

Download F64 Data Sheet Download F72 Data Sheet Download Air Intake Filter Fill-In Sheet

Stoddard Silencers, Inc.
1017 Progress Drive, Grayslake, IL 60030

Proudly Manufactured in the United States

847-223-8636
800-610-0790

847-223-8638

info@stoddardsilencersinc.com