Inlet Air Filter Silencers (Cartridge Filters)
F64 / F72 Series
F64 / F72 Series

The air intake filters & silencers offered by Stoddard Silencers include the F64 and F72 series. The standard models from size 1″ to 8″ are considered air filter silencers while for sizes 10″ – 14″, the units are intake air filters only. Primarily used as air intake filters for blowers, these units can be used wherever ambient air is drawn into a process system to maintain efficiency and prevent performance degradation.
The F64 series includes a paper filter element while the F72 series features a polyurethane filter element. Other air intake filter elements are available on request as shown below. Custom blower filter elements with different dimensions or filtration levels are available on request as well.
The F64 Air Intake Filters provide maximum air filtration (99% on 1 micron), while the 8″ & smaller units provide additional noise silencing as well. For optimum silencing, the F64 can be paired with a chamber-only or chamber-absorptive intake silencer. When used without an intake silencer, the F64 can mount directly on the inlet of an engine, blower or compressor.
Air is drawn into the F64 housing from the underside with the weatherhood protecting from the elements. Particulate is removed from the airstream as the air passes through the replaceable filter element and moves through the outlet of the housing. The filter element should be replaced when the pressure drop across the element is greater than 15″ W.C. differential. For ease of reference, Stoddard Silencers recommends the use of the A40-108 Pressure Drop Indicator for tracking the performance of the filter element.
All welded construction of Carbon Steel sheet metal with 304/316 Stainless Steel available on request. For added convenience, the 10-14″ filters utilize an aluminum cover. Filters of size 8″ and smaller are powder coated, while larger are finished with a gray enamel. Outlet connection features either a plate flange matching the 125/150# ANSI bolt pattern or MPT pipe connection. Washable filter elements, pressure drop indicators and custom outlet connections available on request.
| Model | Part # | A Connection Size | B | C | D | Rated CFM | Wt. (Lbs.) | Replacement Element Number | 2D PDF | 3D STEP |
|---|---|---|---|---|---|---|---|---|---|---|
| F64-1 | 46041* | 1″ NPT | 10 | 4 | 7 | 35 | 7 | F8-108 | ||
| F64-1.5 | 46042* | 1.5″ NPT | 10 | 4 | 7 | 80 | 7 | F8-108 | ||
| F64-2 | 46043* | 2″ NPT | 10 | 4 | 7 | 135 | 7 | F8-108 | ||
| F64-2.5 | 46044* | 2.5″ NPT | 10 | 4 | 7 | 180 | 9 | F8-108 | ||
| F64-3 | 46045* | 3″ NPT | 16 | 5 | 8 | 285 | 9 | F8-109 | ||
| F64-4 | 46046* | 4″ NPT | 16 | 5 | 8 | 520 | 17 | F8-109 | ||
| F64-5 | 46047* | 5″ NPT | 16 | 5 | 8 | 750 | 19 | F8-109 | ||
| F64-5 | 46140* | 5″ FLG | 16 | 5 | 8 | 750 | 19 | F8-109 | ||
| F64-6 | 46048* | 6″ FLG | 20 | 5 | 8 | 1235 | 26 | F8-110 | ||
| F64-8 | 46049* | 8″ FLG | 20 | 10 | 13 | 2125 | 50 | F8-111 | ||
| F64-10 | 46B223* | 10″ FLG | 26 | 15 1/2 | 20 | 3335 | 58 | F8-137 | ||
| F64-12 | 46B267 | 12″ FLG | 26 | 15 1/2 | 20 | 4675 | 68 | F8-137 | ||
| F64-14 | 46B268 | 14″ FLG | 26 | 15 1/2 | 20 | 5655 | 80 | F8-137 |
Part numbers with (*) are typically in-stock to ship 1-2 days ARO.
The F72 Air Intake Filters provide standard air filtration (98% on 10 micron), while the 8″ & smaller units provide additional noise silencing as well. For optimum silencing, the F64 can be paired with a chamber-only or chamber-absorptive intake silencer. When used without an intake silencer, the F72 can mount directly on the inlet of an engine, blower or compressor.
Air is drawn into the F72 housing from the underside with the weatherhood protecting from the elements. Particulate is removed from the airstream as the air passes through the washable filter element and moves through the outlet of the housing. The filter element should be replaced when the pressure drop across the element is greater than 15″ W.C. differential. For ease of reference, Stoddard Silencers recommends the use of the A40-108 Pressure Drop Indicator for tracking the performance of the filter element.
All welded construction of Carbon Steel sheet metal with 304/316 Stainless Steel available on request. For added convenience, the 10-14″ filters utilize an aluminum cover. Filters of size 8″ and smaller are powder coated, while larger are finished with a gray enamel. The outlet connections are either NPT pipe or plate flanges drilled to match 125/150# ANSI bolt pattern. Pressure drop indicators and custom outlet connections available on request.
| Model | Part # | A Connection Size | B | C | D | Rated CFM | Wt. (Lbs.) | Replacement Element Number | 2D PDF | 3D STEP |
|---|---|---|---|---|---|---|---|---|---|---|
| F72-1 | 46301* | 1″ NPT | 10 | 4 | 7 | 35 | 9 | F8-119 | ||
| F72-1.5 | 46302* | 1.5″ NPT | 10 | 4 | 7 | 80 | 9 | F8-119 | ||
| F72-2 | 46303* | 2″ NPT | 10 | 4 | 7 | 135 | 10 | F8-119 | ||
| F72-2.5 | 46304* | 2.5″ NPT | 10 | 4 | 7 | 180 | 10 | F8-119 | ||
| F72-3 | 46305* | 3″ NPT | 16 | 5 | 8 | 285 | 20 | F8-120 | ||
| F72-4 | 46306* | 4″ NPT | 16 | 5 | 8 | 520 | 20 | F8-120 | ||
| F72-5 | 46307* | 5″ NPT | 16 | 5 | 8 | 750 | 23 | F8-120 | ||
| F72-5 | 46H338* | 5″ FLG | 16 | 5 | 8 | 750 | 23 | F8-120 | ||
| F72-6 | 46308* | 6″ FLG | 20 | 5 | 8 | 1235 | 40 | F8-121 | ||
| F72-8 | 46309* | 8″ FLG | 20 | 10 | 13 | 2125 | 50 | F8-122 | ||
| F72-10 | 46310 | 10″ FLG | 26 | 15 1/2 | 20 | 3335 | 95 | F8-123 | ||
| F72-12 | 46311 | 12″ FLG | 26 | 15 1/2 | 20 | 4675 | 100 | F8-123 | ||
| F72-14 | 46324 | 14″ FLG | 26 | 15 1/2 | 20 | 5655 | 115 | F8-123 |
Part numbers with (*) are typically in-stock to ship 1-2 days ARO.
Stoddard Silencers offers multiple options for blower filter elements as listed below. The F64 series comes standard with the paper filter element while the F72 series features a polyurethane element.