Blower Silencer – Silencing 101

Learn about blower silencers and their design and function

PD Blower Silencer Pacakge

An Industrial Blower Silencer is designed to reduce the pulsation and noise generated by the passage of the lobes inside of a positive-displacement blower (aka a Roots blower). As the noise is generated from within the blower, the noise will travel in every direction, so not only with the path of the airstream but also the blower inlet, jetport (where applicable) and the casing of the blower. By installing a blower silencer to your system, this will help reduce the noise in the environment around the blower and assist in the process line as well.

Blower Silencer Applications

Because the noise moves in multiple directions, Stoddard Silencers offers different blower silencers to help address all possible noise in the process.

  • Intake Filter Silencer
    • The F64 and F72 series intake filter/silencers provide filtration of the intake air on a pressure system while reducing the noise coming from the blower. Note that while airflow is moving through the intake filter/silencer to the blower and further, the noise will also radiate back through the inlet opening of the filter.
  • Intake Silencer
    • Typically used on Pressure Systems, the intake silencer is used to reduce the amount of noise moving through the inlet side of the blower.
  • Discharge Silencer
    • In a Pressure System, the discharge silencer is not only used to reduce the noise moving downstream in the process line but also to reduce the pulsation of the blower to provide a smoother process flow.
    • In a Vacuum System, the discharge silencer is used to reduce the noise of the air before it is discharged into the surrounding environment.

Blower Silencer Types

Based upon the blower gear diameter and the RPM of the blower (not the motor), it can be determined whether the blower is running above or below Transition Speed. For blowers operating below transition speed, the majority of the noise generated is low-frequency noise. As the blower moves closer to and above the transition speed,  more high frequency noise is generated and becomes necessary to target that part of the noise spectrum.

  • Chamber-Only Silencers: For blowers operating below transition speed, Stoddard Silencers recommends chamber-only silencers. These silencers rely on internal reflection within the chambers of the silencer to reduce the mid and low frequency noises generated by the blower.
  • Chamber-Absorption Silencers: When the blower operates near or above transition speed, Stoddard Silencers recommends chamber-absorptive silencers. These utilize the chamber design of the chamber-only silencers while also incorporating a section of acoustic ‘packing’ designed to effectively reduce the high frequency noise now generated by the blower.
  • Absorption Silencers:  For smaller blower systems running at high RPM, some customers will opt for an absorptive-only silencer which relies solely on acoustic ‘packing’ to reduce high frequency noise as the blower’s pulsations are not significant enough to be audible.  Additionally, L21 and C26 absorption silencers are installed systems that require additional silencing above the performance of the original silencer or as a secondary silencer

Blower Silencer Sizing

In order to determine the appropriate model & size silencer, we require the operating conditions of the blower. Be aware that sometimes the operating conditions are significantly different than the maximum conditions possible of the blower. The information required is:

  • Blower Make & Model
  • Discharge Pressure (if used in a pressure system)
  • Inlet Vacuum (if used in a vacuum system)
  • ICFM of the Blower
  • Operating RPM of the Blower
    • Note that the RPM of the Blower can be different than the RPM of the motor.
    • Note that many blower systems are not running at the maximum rated RPM of the blower.
  • Discharge Temperature


Utilizing the above information, Stoddard Silencers can recommend the optimal silencer for your application. Contact Us today to see how we can optimize the silencers on your blower system.

Design & Installation Considerations

  • Nozzle Loads: The inlet and outlet nozzles are not designed to support the weight of the silencer or external piping. The silencer should be isolated from the blower and any upstream/downstream piping via flex connectors to prevent stress and cracking around the circumferential weld between the nozzle and the shell or head.
  • Silencer Support: Stoddard Silencers recommends utilizing our A11 Vertical Mounting Legs, A12 Horizontal Mounting Saddles or A14 Horizontal or Vertical Mounting Clips.
  • Standing Waves: The intake and discharge silencers must be located as close to the blower as possible. This requirement is due to the potential of harmful standing waves if the piping extends further. If the silencer cannot be positioned close to the silencer, please contact us to determine the maximum recommended distance between the silencer and blower.
  • For more information, please see our Installation and Operations Manuals for the appropriate silencer(s).

Need help determining the correct blower silencer? Use the below fill-in sheet to complete the necessary information for quoting.

PD Blower Silencer Fill-In Sheet

Stoddard Silencers, Inc.
1017 Progress Drive, Grayslake, IL 60030

Proudly Manufactured in the United States

847-223-8636
800-610-0790

847-223-8638

info@stoddardsilencersinc.com

© 2026 Stoddard Silencers    |   Site by Soapbox Studio |   Privacy Policy